Macrogen has served over 10 years in sequencing field using the cutting edge technology and delivering fast and reliable results. We use state-of-the-art high throughput Applied Biosystems 3730XL sequencers.
We sequence all kinds of cloned DNAs (plasmids, cosmid, phages, BACs) as well as PCR-products.
Macrogen provides a high quality DNA Sequencing service for academics, government, research institutions and private companies at Very Competitive Price.
Please contact us for any inquiry.

For more detailed explanations and recommendations about the preparation and submission of samples, please refer to the following link:
Download 'Single Pass Sequencing Sample Submission Guide' (English)
Download 'Single Pass Sequencing Sample Submission Guide' (Spanish)

To order the sequencing service, please access to our online ordering system and create an account;
http://dna.macrogen-singapore.com/eng

For payment information, please refer to the following link:
Download 'Payment Information'
http://dna.macrogen-singapore.com/eng/account/guide/howtopay.jsp

Contact
Sequencing Inquiry: info-sg@macrogen.com
Payment Inquiry: payment-sg@macrogen.com
Genome and Project sequencing inquiry: ngs.apac@macrogen.com

Technical Support
Macrogen-Korea : Macrogen-Korea
Macrogen-Europe : Macrogen-Europe
Macrogen-Spain : Macrogen-Spain
Macrogen-Singapore : Macrogen-Singapore

Shipping Address (for Value Service to Macrogen Inc.)
Macrogen Inc.
#1001, 254 Beotkkot-ro,
Geumcheon-gu, Seoul,
SEOUL 08511 Rep. of KOREA

Tel : +82-2-2113-7054
Fax : +82-2-2180-7100
E-mail : info-sg@macrogen.com

Shipping Address (For European Express Service to Macrogen Europe)
Macorgen Europe
 Meibergdreef 31
1105 AZ, Amsterdam
the Netherlands

Tel : +31-20-333-7563
E-mail : europe@macrogen.com

Shipping Address (For Spanish, Portuguese and Italian Express Service to Macrogen Spain)
Macorgen Spain
 Avda Sur del aeropuerto de Barajas 28, PB
28042 Madrid

Tel : +34 911 138 378
E-mail : info-spain@macrogen.com


Prepare samples and primers
Template/Service Concentration Sample Volume Primer Volume
+ Concentration
Plasmid
(below 4kb )
100~150ng/ul 5ul for 1st reaction + 5ul for re-trial reaction 5ul + 5pmol/ul
Plasmid
(over 4kb)
200ng/ul 5ul for 1st reaction + 5ul for re-trial reaction 5ul + 5pmol/ul
PCR product(below 200bp)
Purified / Unpurified
10ng/ul 5ul for 1st reaction + 5ul for re-trial reaction 5ul + 5pmol/ul
PCR product(201bp~500bp)
Purified / Unpurified
20ng/ul 5ul for 1st reaction + 5ul for re-trial reaction 5ul + 5pmol/ul
PCR product(over 500bp)
Purified / Unpurified
Over 25ng/ul 5ul for 1st reaction + 5ul for re-trial reaction 5ul + 5pmol/ul
PCR product(over 1000bp)
Purified / Unpurified
30~60ng/ul 5ul for 1st reaction + 5ul for re-trial reaction 5ul + 5pmol/ul
BAC Over 500ng/ul 5ul for 1st reaction + 5ul for re-trial reaction 5ul + 10pmol/ul
16S/18S/26S rRNA & ITS
region full Sequencing
(Agar Plate/Glycerol Stock)
gDNA: 30-50ng Minimum volume of 50ul
Difficult Sequencing 100 ng/ul Minimum volume of 40ul
Primer Walking 8 µg
(for an insert size of up to 4kb)
Minimum volume of 50ul

Note :
1. Primer Walking - Single Strand Sequencing: 1µg/1 kb insert. If insert size is longer than 4kb, clone is required in an agar stab culture status.
2. If you have a blood and tissue of insect/plant/animal or something, please contact us by email. info-sg@macrogen.com



a) Sample for individual tube :
- General glycerol stock/ Agar-stab/Agar-plate culture at room temperature.
- 1.5mL Microcentrifuge Tube is recommended in a dried (lyophilized) form or solution
..(Nuclease-free TE or distilled water) at room temperature..
- Free re-sequencing is included
b) 96 Well Plate :
- 8 strip cap is recommended in a dried (lyophilized) form or solution (Nuclease-free TE or distilled water)
.. at room temperature.
- Re-sequencing is additionally charged.

** In case of Multi primers for one plate **
Only two custom primers (or two universal primers) in tubes could be acceptable for applying this Plate sequencing.

* Note:
- The well to well variation of the concentration of your samples is very important to get
   better results, please keep it as constant as possible.



- Please prepare samples to avoid any well-to-well concentration difference or size differencefor
  quality results.

c) Primer :
- Primer : 5 pmol/ul in 20ul based on 5 samples
- Primer Tm is suitable for service : 55°C ~ 60°C
- Commonly used Universal primers are available for free of charge (ex. M13F, T7, T3)
- Design and synthesize primers if you request. (US$0.25/base)

It is possible to send either a stab or glycerol culture with the selected E.coli clone, the purified plasmid DNA or your unpurified or purified PCR product.
Templates and primers must be provided in DI water or 10mM Tris buffer, not in TE
d) To apply Plate sequencing :
- 1 primer/ 1plate service : It is for covering one type of primer all through out the plate for clients who wish to run sequencing using
  only primer through out the samples in the plate. If the client for example wish to run the sample plate with samples 1~96 using
  primer 2, same price rate for 1Primer/1Plate service will be added.


- Multi primers/ 1plate service: This service is for clients who wish to run small numbers of different samples using different primers.
  This service allows up to usage of 6 different primers under one plate service count covering 96 samples.